Sign In | Join Free | My uabig.com |
|
Model Number : NetEngine 8000 M4
Type : Enterprise Router
Place of Origin : Beijing, China, guangdong, China
Brand Name : HW
Use : core, aggregation, and access networks
Network : Wireless Lan, Wired LAN, ONVIF, SDK, TCP
Products Status : Stock
Function : SNMP, VLAN Support
WAN Ports : 1
Weight (lb/kg) fully configured : 9.9 kg (21.78 lb)
Throughput : 1.44 Tbps
Operating temperature : 32° to 104° F (0° to 40° C)
Traffic analysis : NetStream
VLAN : Adding access, trunk, and hybrid interfaces to VLANs/Default VLAN
Dimensions (H x W x D) : 335 mm x 585 mm x 390 mm (13.19 in. x 23.03 in. x 15.35 in.)
Packaging Details :
1,Carton packing or wooden case packing according to customer requirements
2,Sufficient protective materials are added to the packing box to effectively prevent the product from being damaged due to turbulence during transportation.
Supply Ability : 1000 Carton/Cartons per Day
Price : $2,500.00 - $32,000.00/pieces
Cabinet installation standards | ETSI (21-inch); IEC (19-inch) |
Dimensions without packaging (H x W x D) [mm(in.)] | 88.9 mm x 442 mm x 220 mm (3.5 in. x 17.4 in. x 8.66 in.) |
Dimensions with packaging (H x W x D) [mm(in.)] | 335 mm x 585 mm x 390 mm (13.19 in. x 23.03 in. x 15.35 in.) |
Chassis height [U] | 2 U |
Weight without packaging [kg(lb)] | 7.2 kg (15.87 lb) |
Weight with packaging [kg(lb)] | 9.9 kg (21.78 lb) |
Weight without packaging (full configuration) [kg(lb)] | 10.4 kg |
Weight with packaging (full configuration) [kg(lb)] | 13.1 kg |
Typical power consumption (with configuration) [W] | 283.4 W |
Typical heat dissipation (with configuration) [BTU/hour] | 919.47 BTU/hour |
MTBF [year] | 33.40 year |
MTTR [hour] | 0.5 hour |
Availability | 0.999998291 |
CPU | 16-core, 2.0 GHz |
SDRAM | 16GB |
Flash memory | 64MB |
Storage | 16 GB |
Power supply mode | DC |
Rated input voltage [V] | –48 V/–60 V |
Input voltage range [V] | –40 V to –72 V |
Maximum input current [A] | 30 A |
Rated output power [W] | 1200 W |
Maximum input cable size [mm²] | 4 mm^2 (0–14 m) |
Front-end circuit breaker/fuse [A] | ≥ 16 A (Based on long-term evolution requirements and site conditions, the recommended current is greater than or equal to 32 A.) |
Heat dissipation mode | Air cooling |
Airflow direction | From left to right |
Noise at normal temperature (acoustic power) [dB(A)] | < 65 dB(A) |
Number of slots | 8 |
Number of service board slots | 6 |
Switching capacity | 2.4 Tbit/s (Bidirectional) |
Maximum number of physical ports on the entire device | 116 |
Maximum number of 100GE ports | 12 |
Maximum number of 50GE ports | 12 |
Maximum number of 40GE ports | 12 |
Maximum number of 25GE ports | 64 |
Maximum number of 10GE ports | 72 |
Maximum number of GE ports | 96 |
Maximum number of FE ports | 96 |
Maximum number of electrical ports | 96 |
Redundant power supply | 1+1 |
Redundant fans | 1+1. Short-term running when a single fan becomes invalid at the ambient temperature of 40°C (104°F) (one fan module contains two fans) |
Long-term operating temperature [°C(°F)] | -20°C to 60°C(-4.0°F to 140.0°F) |
Restriction on the operating temperature variation rate [°C(°F)] | ≤ 30°C/hour (54°F/hour) |
Storage temperature [°C(°F)] | –40°C to +70°C (–40°F to +158°F) |
Long-term operating relative humidity [RH] | 5% RH to 85% RH, non-condensing |
Short-term operating relative humidity [RH] | 5% RH to 95% RH, non-condensing |
Storage relative humidity [RH] | 5% RH to 95% RH, non-condensing |
Long-term operating altitude [m(ft.)] | ≤ 4000 m (13123.2 ft.) (For the altitude in the range of 1800 m to 4000 m [5905.44 ft. to 13123.2 ft.], the operating temperature of the device decreases by 1°C [33.8°F] each time the altitude increases by 220 m [721.78 ft.].) |
Storage altitude [m(ft.)] | < 5000 m (16404.20 ft.) |
![]() |
Fully Configured NetEngine 8000 M4 DC Chassis 9.9 kg 21.78 lb with DC Power and Fan Box Images |